Kang Yu-Control Systems Engineering Co., Ltd.
| 中文EnglishWap
Your are here| Home | Products |Automobile Sensors
Product name:Reducing Valves Pressure Sensors
The product model:KYAB03WL Series

application:Mainly use to detect the cylinder gas pressure, and shows directly the remaining amount of pressure through the supporting the display meter, to remind drivers refilling.

 
  • Details
  • Specifications
  • Product Diagram
  •  

    Description

    KYAB03 series pressure sensors use imported special steeland specialall-metalpackage, with high reliable amplified compensated circuits, change the media pressure into standard electrical signal.  High-quality sensing element, superpackaging technology and perfect assembly process ensure high quality and excellent performance.  There are a variety of interface ports and cables out to satisfy the needs of customers.  Operating temperature range -40~125℃. They are mainlyused to measure various pressures in automobile, air conditioners and other related pressures monitoring systems.

     

    Applications

    CNG、LNG、LPG gas pressure Motor oilpressure

    HVAC / Rair conditioning and refrigeration

    Automotivebrake pressure
    Industrial process measurement and control
    Pressure on other non-corrosive liquids or gases

     

    Features:

    ◆No O-ring, leakage and over-loaded performance is better than ceramics,Straingaugeand other principleproducts

    ◆Multi range available

    ◆High Accuracy, stability and reliability

    ◆Goodcorrosion-proof

    ◆Digital compensated, excellent temperature characteristics

    ◆Reverse protection, short circuit protection;

    ◆Small size, compact appearance, cost-effective

    Specifications:

     

     Parameter

    Value 

    Units

    Operating Voltage

    5/12/24

    VDC

    ThreadPort

    G1/4 or customized

    ——

    Media

    Clean gas or liquid

    ——

    PressureRange

    0~26 or customized

    MPa

    Performance guarantee pressure

    40

    MPa

    Burst Pressure

    60

    MPa

    Output Voltage

    0.5~4.5

    VDC

    Error in normal temperature

    ±1

    %FS

    Error within operating temperature

    ±3

    %FS

    Operating Temperature

    -40~125

    Storage Temperature

    -40~125

    Operating Current

    <10

    mA

    Long-term Stability

    ±1

    %FS/year

    Insulation Resistance

    >50

    MΩ/50VDC

    Response Time

    2

    ms

     

    Application Description

    Mainlyuse to detect the cylinder gas pressure, and shows directly the remaining amount of pressure through the supporting the display meter, to remind drivers refilling.

    Products Diagram

     

     

     

    Gross Weight: 60g

    Net Weight:57g

    Copyright@2014 bob体育手机版_bob平台注册_bob官网地址 Design: Sirui network